Secondary Nodes and Junction Boxes

Secondary Nodes and Junction Boxes

MJ03C Installed in International District Field

On July 20, the medium-power junction box MJ03C was installed in the International District hydrothermal vent field on ROPOS Dive R1717. It was

MJ03C Installed in International District Field

On July 20, the medium-powere junction box MJ03C was installed in the International District hydrothermal vent field on ROPOS Dive R1717. It was connected to a ~2300-m-long cable (RSO3W6) that will connect this system to Primary Node PN3B. A temperature-resistivty sensor (TRHPHA301) is inside the J-Box, awaiting installation during a follow-on dive. Photo credit: NSF-OOI/UW/CSSF; Dive 1717; V14.

×
Thermistor Array Ready for Testing

Medium Powered J-Box MJ03B in the ASHES hydrothermal field. A 3D thermistor array is attached to the J-Box. Photo credit: NSF-OOI/UW/CSSF.

Thermistor Array Ready for Testing

The 3D thermistor array designed by RSN Project Scientist Giora Proskurowski is attached to the Medium Powered J-Box (MJ03B) in the ASHES hydrothermal field. In 2014, the array was deloyed in a diffuse flow site at the base of the vent called Mushroom, along with a high-definition video camera and an osmo vent fluid sampler. VISIONS '13, Leg 4

Photo credit: NSF-OOI/UW/CSSF.

×

Low- and Medium-Power Junction Boxes and Low-Voltage Nodes on the OOI Cabled Array direct power and communications to experimental sites. This infrastructure provides 375 Vdc to 12 V power to sensor arrays on the seafloor and on water-column moorings, and 10 Gb/s to 1 Gb/s bandwidth. Eight instrument ports provide 12 to 48V and 10/100BASE-T, RS232 or RS485 data links. Nodes can be daisy-chained, thereby providing extensive expansion capabilities for future science and education efforts.

MJ03C Installed in International District Field

On July 20, the medium-power junction box MJ03C was installed in the International District hydrothermal vent field on ROPOS Dive R1717. It was

MJ03C Installed in International District Field

On July 20, the medium-powere junction box MJ03C was installed in the International District hydrothermal vent field on ROPOS Dive R1717. It was connected to a ~2300-m-long cable (RSO3W6) that will connect this system to Primary Node PN3B. A temperature-resistivty sensor (TRHPHA301) is inside the J-Box, awaiting installation during a follow-on dive. Photo credit: NSF-OOI/UW/CSSF; Dive 1717; V14.

×
Thermistor Array Ready for Testing

Medium Powered J-Box MJ03B in the ASHES hydrothermal field. A 3D thermistor array is attached to the J-Box. Photo credit: NSF-OOI/UW/CSSF.

Thermistor Array Ready for Testing

The 3D thermistor array designed by RSN Project Scientist Giora Proskurowski is attached to the Medium Powered J-Box (MJ03B) in the ASHES hydrothermal field. In 2014, the array was deloyed in a diffuse flow site at the base of the vent called Mushroom, along with a high-definition video camera and an osmo vent fluid sampler. VISIONS '13, Leg 4

Photo credit: NSF-OOI/UW/CSSF.

×